I have parametro call client, who is a list of clients, taken from the data
base to traves of a query, access the report through the URL, by means of
Internet to explorer, in some cases desire of passing parameter clients
already selected and who the user who is seeing the report cannot modify it,
As blockade the parameter?
--
ING. JOSE DAVID GALVIZ MUÑOZ
MCAD
DCE Tercera EstrellaHi Jose,
You can, either when designing the report or through Report Manager set the
parameter to No prompt. When you do this, the parameter will not be
displayed to the user, so the user will not be able to change the value.
-Lukasz
--
This posting is provided "AS IS" with no warranties, and confers no rights.
"José David Galviz M" <joda_26@.hotmail.com> wrote in message
news:Okp1lnQcEHA.644@.tk2msftngp13.phx.gbl...
>I have parametro call client, who is a list of clients, taken from the data
> base to traves of a query, access the report through the URL, by means of
> Internet to explorer, in some cases desire of passing parameter clients
> already selected and who the user who is seeing the report cannot modify
> it,
> As blockade the parameter?
> --
> ING. JOSE DAVID GALVIZ MUÑOZ
> MCAD
> DCE Tercera Estrella
>|||Thanks
--
ING. JOSE DAVID GALVIZ MUÑOZ
MCAD
DCE Tercera Estrella
"Lukasz Pawlowski [MSFT]" <lukaszp@.online.microsoft.com> escribió en el
mensaje news:O%23bJnl1cEHA.1000@.TK2MSFTNGP12.phx.gbl...
> Hi Jose,
> You can, either when designing the report or through Report Manager set
the
> parameter to No prompt. When you do this, the parameter will not be
> displayed to the user, so the user will not be able to change the value.
> -Lukasz
> --
> This posting is provided "AS IS" with no warranties, and confers no
rights.
>
> "José David Galviz M" <joda_26@.hotmail.com> wrote in message
> news:Okp1lnQcEHA.644@.tk2msftngp13.phx.gbl...
> >I have parametro call client, who is a list of clients, taken from the
data
> > base to traves of a query, access the report through the URL, by means
of
> > Internet to explorer, in some cases desire of passing parameter clients
> > already selected and who the user who is seeing the report cannot modify
> > it,
> > As blockade the parameter?
> >
> > --
> > ING. JOSE DAVID GALVIZ MUÑOZ
> > MCAD
> > DCE Tercera Estrella
> >
> >
>
Subscribe to: